PRODUCT
Glass/Ceramic Calibration Board
GLASS/CERAMIC HALCON CALIBRATION BOARD

It is used to calibrate the image system, which is necessary for high-precision positioning, measurement and inspection image systems.

Expand details
Put away
main feature
Ultra high precision. Various sizes, customized graphics. Materials include: glass, quartz, ceramics, film, photo paper, metal substrates are optional.

Glass calibration plate-photolithography process, the physical error of a single pattern of standard precision is within 1μm, and the physical error of adjacent patterns is ±1μm.

The highest accuracy can be 0.5μm. The maximum size is 1000x1000mm.

Ceramic calibration plate-diffuse reflection, completely eliminate reflection, the physical error of single pattern accuracy is within 1μm, and the physical error of adjacent patterns is ±1μm. The maximum size is 200x200mm.


main feature

Internationally accepted test standards.

Standard specifications of Halcon calibration board:


Halcan


CHG-038-3.0

  Dimensions 38*38; graphics size with borders 25.6*25.6;

  Dot diameter 1.5; Dot center distance 3.0

CHG-050-4.0

  Dimensions 50*50; graphics size with borders 34*34;

  Dot diameter 2.0; Dot center distance 4.0

CHG-076-6.0

  Dimensions 76*76; frame size 51*51;

  Dot diameter 3.0; dot center distance 6.0

CHG-100-8.0   

  The overall size is 100*100; the frame size is 68*68;

  Dot diameter 4.0; dot center distance 8.0

OPENCV GLASS/CERAMIC CALIBRATION BOARD

Ultra high precision. Various sizes, customized graphics. Materials include: glass, quartz, ceramics, film, photo paper, metal substrates are optional.

Expand details
Put away
main feature
Ultra high precision. Various sizes, customized graphics. Materials include: glass, quartz, ceramics, film, photo paper, metal substrates are optional.

Glass calibration plate-photolithography process, the physical error of a single pattern of standard precision is within 1μm, and the physical error of adjacent patterns is ±1μm.

The highest accuracy can be 0.5μm. The maximum size is 1000x1000mm.

Ceramic calibration plate-diffuse reflection, completely eliminate reflection, the physical error of single pattern accuracy is within 1μm, and the physical error of adjacent patterns is ±1μm. The maximum size is 200x200mm.

main feature

Internationally accepted test standards.

OpenCV calibration board standard specifications:


OpenCV 


COG-050-0.5

 Dimensions 50*50;

Frame size 25.5*25.5; box size 0.5

COG-076-1.0

Dimensions 76*76;

Frame size 51*51; box size 1.0

COG-100-2.0

 Overall size 100*100;

Frame size 74*74; square size 2.0

COG-100-6.0 

 Overall size 100*100;

Frame size 74*74; box size 6.0

CHECKERBOARD CALIBRATION BOARD

Ultra high precision. Various sizes, customized graphics. Materials include: glass, quartz, ceramics, film, photo paper, metal substrates are optional.

Expand details
Put away
main feature
Ultra high precision. Various sizes, customized graphics. Materials include: glass, quartz, ceramics, film, photo paper, metal substrates are optional.

Glass calibration plate-photolithography process, the physical error of a single pattern of standard precision is within 1μm, and the physical error of adjacent patterns is ±1μm.

The highest accuracy can be 0.5μm. The maximum size is 1000x1000mm.

Ceramic calibration plate-diffuse reflection, completely eliminate reflection, the physical error of single pattern accuracy is within 1μm, and the physical error of adjacent patterns is ±1μm. The maximum size is 200x200mm.

main feature

Internationally accepted test standards.
Checkerboard Standard Specification of Calibration Board:


棋盘格


CTG-038-0.2

 Dimensions 38*38;

Graphic size 20.6*20.6; square size 0.2

CTG-050-0.5

 Dimensions 50*50;

Graphic size 25.5*25.5; square size 0.5

CTG-076-1.0

Dimensions 76*76;

Graphic size 51*51; box size 1.0

CTG-100-2.0 

Overall size 100*100;

Graphic size 74*74; box size 2.0

DOT CALIBRATION BOARD

Glass calibration plate-photolithography process, the physical error of a single pattern of standard precision is within 1μm, and the physical error of adjacent patterns is ±1μm.


The highest accuracy can be 0.5μm. The maximum size is 1000x1000mm.

Expand details
Put away
main feature
Ultra high precision. Various sizes, customized graphics. Materials include: glass, quartz, ceramics, film, photo paper, metal substrates are optional.

Glass calibration plate-photolithography process, the physical error of a single pattern of standard precision is within 1μm, and the physical error of adjacent patterns is ±1μm.

The highest accuracy can be 0.5μm. The maximum size is 1000x1000mm.

Ceramic calibration plate-diffuse reflection, completely eliminate reflection, the physical error of single pattern accuracy is within 1μm, and the physical error of adjacent patterns is ±1μm. The maximum size is 200x200mm.

main feature

Internationally accepted test standards.
Standard specification of dot calibration board:


Dots CDG-038-0.2

Shape size 38*38; Graphic size 20*20;

Dot diameter 0.1; dot center distance 0.2

CDG-050-0.5

Overall size 50*50; Graphic size 25*25;

Dot diameter 0.25; dot center distance 0.5

CDG-076-1.0

Dimensions 76*76; Graphic size 51*51;

Dot diameter 0.5; Dot center distance 1.0

CHG-100-8.0

 Overall size 100*100; graphic size 74*74;

Dot diameter 1.0; Dot center distance 2.0

USAF 1951 resolution test board

It can intuitively evaluate the resolving power of the lens, an international test benchmark

Expand details
Put away
product description
The resolving power of the lens can be evaluated intuitively.

main feature

Internationally accepted test standards.
Checkerboard Standard Specification of Calibration Board:


USAF 1951


CUG-050-0

   Dimensions 50*50; the largest group is 0 group

CUG-076-2

  Dimensions 76*76; the largest group is -2 groups